hayward blue essence troubleshooting

Not sure if this is somehow related to the water being heated or maybe air in the pump just guesses. Any suggestions? If you can remove the handle, you can apply shaving cream and run the pump to see if it gets sucked in put cream around the stem and on both joints in/out of the valve. Air can also be drawn into the pump from leaky suction side valves (skimmer or main drain). Just replaced the sand and cleaned the fingers, replaced the o rings and have a psi of 15 and great suction. Is the wire the correct size wire? outlet still on. "url": "https://blog.intheswim.com/"
},
Reset the average salt level on startup and whenever you replace your cell. what do you think the hum could be? I have a 2 year old Hayward Pump 1 HP wired for 110 with 20 Amp breaker. Hayward Pool Pump Troubleshooting - In The Swim Pool Blog You can check the visual motor check (if you have an intermatic clock), to see if the motor gears are turning, which means the timeclock motor is good and the power from the breaker is good. Not sure power goes to the pump. Well the electrician said it was a bad motor and to contact hayward to replace. If you have power coming into the motor, but no pump noise, check (Power off) that wire connections are tight, and inspect the wire for breaks or damage. I recently noticed what appears to be a shaft seal leak. Your 1 hp Hayward Superpump can pump 75 gallons per minute, which is too much flow for most AG pool filters. I let it cooled down tho the temp was only 90 at that time. Hi Josh, that sounds like the Display board, a circuit board that controls the display. Please let me know what can be done if anything we may be calling for info. There are some pumps that will draw air in thru a faulty shaft seal, which will leak water, dripping below the pump, when the pump shuts off. After Irma came through, we were without power for a week, the pump wont run on low speed and when it runs at high speed, it overheats after about an hour and shuts off. Wouldnt, the other three still be sufficient to filter? Or to a light switch and then to a breaker, that would be more of a standard installation. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). 24V after the transformer is present. Backwash your filter when pressure gauge rises 7-9 psi above the clean, starting pressure. "@type": "BlogPosting",
The process, for changing a hayward pump seal is: 1. Hi Dave, the square gasket for the lid, can sometimes come out of the groove on a Superpump, Id check that first, and make sure the lid is very tight. started having the problem There was alot of debris once I removed the assemblies and some water below wiring. Use the [7/16] wrench to wiggle the shaft through several revolutionsto free up the shaft. Usually however, a howling or moaning sound from the pool heater, is low water flow. See below for more detail. Hi my spa empties into the pool when the spa is turned on. It runs fine but no strong circulation. Like it is getting through the shaft seal but the seal is brand new.. any thoughts? So, it could be a problem with the cord, or the connection on the other end of the cord, likely if the motor is making no noise at all. Hi, Is it possible pump too small for AV60 filter? If it slowly rises your capacitor is capable of holding a charge. If they wont or cant fix it, call a electric motor repair shop to visit, or pull the pump and take it to them for service, or attempt the (easy) repair yourself. I can see the water trickling in to the filter after a while, and the output becomes very limited. 99% of the time its no problem 1% of the time something could burst, usually a plumbing fitting, a bad glue joint or clamped fitting. Is this the problem and should I get i checked or just replace it? What can be the cause? Hi Tommy, very loud pump could be that the pump overheated, because it lost prime, and this either damaged the shaft bearings or melted/warped the impeller and diffuser. When I then switch the pump breaker off and then back on again it springs into life (every time). Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. The higher the pump is elevated above the water level, the more struggles this can cause. There is water under the motor not sure from where. For over 2 months, lots of troubleshooting, actually RE-PIPED THE SECTION FROM POOL TO PUMP done by professionalpump still will not primedraws water, wont primeplayed with outflow and values, no primetook apart (my nemesis) Hayward Perflex DE filter, cleaned fingers, silicone on gaskets, put back (I have done this crappy job a hundred times so I am familiar with the process)no primefeel like draining the damn pool and junking the whole thing >:(. Just replaced our pool pump, Hayward 1 hp self priming, super pump. Your options are to 1). Hi there, 30 psi is pretty high pressure, sounds like the pump is having trouble pushing thru are you using enough DE powder? If you see an increase in pump pressure, ensure that there is no blockage preventing the flow. Or spray with shaving cream (yes! I opened my pool this weekend and started the pump and let it run for few hours before stopping it. The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. Check the incoming voltage to be sure that you are within the range of 110V-125V. Possibly an obstruction on the return line, after the filter? Thanks, good question. Hi Brian, is this a DE filter? So I installed a brand new Hayward W3SP2610X15 Super Pump Pool Pump, 1.5 HP last season Summer 2019 and used the electric cord from the old one which was showing its age. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Tripping the breaker, could possibly be a bad breaker, allowing too much voltage to pass thru to the pump. Question my Aquaririte is 3 years old. Replaced motor and seal on my Hayward Northstar. Mine just did the same. If the pump plugs into an outlet, I would check the GFCI button to be sure the outlet has not popped or tripped. Third time turned off pump same thing happened with humming and eventually kicking in. Would Hayward do anything for me? Gauge was reading between 6 and 8 on filter container at this time. I took off the cover to see the circuit board and all looks ok but then it started coming on and off randomly while I was standing there. None of the indicating lights are on. Sparking can also come directly from a short in the windings of the motor. Hi Dave, we are replacing a Hayward superpump 1.5 horsepower with the same pump. It could be air in the pump, or it could be that the pump is too big (powerful) for the number of pipes. i cleaned the filter put the cover back on turned the pump but it doesnt seem to be priming . No need to look for a solution after the impeller, its always before, on the suction side. i have a 4 wire set up, ground, line , low speed,high , just want to make sure i wire correctly, 1- line 1, 2- high speed, 3or4 to low speed? Motor air flow path should be checked. The same thing happened to the first one. If so, you may try to glue them in place with JB Weld or similar, and if that doesnt work, a new housing would be in order. So I inspected the wiring into the electrical panel. Hi David, spilling water on the motor is no problem, they do fine outside in the rain (flooding is a different story) Have you checked the GFCI test button on the outlet? "author": {
UNK the , . A lb of DE is by volume, equal to a 1 lb coffee can, or about 4 cups of dry measure. It did not do this until we pressure washer the deck and some wood chips got into the pool. If your salt system is hardwired, variations in voltage could cause the controller to go a little haywire. Hi Chuong, the Leslies RS750CA is the same as the Hayward Super II pump, which are $500-$600. Look closely for any visible damage in the rear of the motor, anything loose, disconnected, chewed, melted, broken, burnt or cracked. 6. inspect conduit and wires going from timer to pump, look for water in the conduit, or broken conduit, or rodent damage to wires. Hi Marshall, check that the water level is good, and skimmer weirs are not stuck, blocking water flow into the skimmer, both cases cause the skimmer to suck air, which cause the pump to lose prime. When turned on, it clicks in and off every few seconds. Relays are usually small cubes, about 1 square, sometimes black, sometimes clear, mounted on a circuit board. But this pump smokes when I try to turn it on (guessing motor burned out from being submerged). You will get much more visibility by. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-heater-troubleshooting/",
Also will need to have clean pump basket and a clean pool filter, to ensure adequate flow rates. Hi Cortney, you can buy the cord separately, Hayward pump cord the cause is likely from something arcing within the plug outlet. Hello. I have a Hayward HeatPro model HP21104T. Backwashing or cleaning the pump basket is the usual fix. Or a loose base part rattling? Maybe does a quarter of a turn. Probably a loose fitting, clamp or o-ring. Just replaced my old Polaris booster pump, 3/4 hp, with a 1hp pump. It ran and then we shut it off. Good luck! Can I replace a specific part or do I have to buy a new one? I owe you a beer if you are ever around my neck of the woods. Troubleshooting Guides To view these documents, you will need to download the free Acrobat Reader, which gives you instant access to PDF files. Step 1: With your pump running, double-check the positions of your valves. So, when a pump is surging or pulsing, and not getting up to full head it is either starved for water, because of closed incoming valves, or too big of a pump for too small inlet pipes or because of air being pulled into the pump from air leaks or low water level in pool or from some obstruction in the lines, pipes or valves, a clog or something broken off I have found a Drain King useful in diagnosing such things, find at a hardware store, the 1.5-2 model, and connect to a garden hose, to pressurize pool systems and pipes, to look for leaks, or used as a water hammer to force clogs out, back the other way. About two weeks ago, my pool water level was very low and I believe this is were the air bubbles first presented. Hi Deb, SF (Sensor Failure) indicates that the temperature sensor (thermistor) is not getting good data to the circuit board. Not that I can think of, but something seems to be aerating your water? Perflex filters can also leak out of the bump handle, this fix usually involves replacing the shaft o-rings. Terrible storms 2 nights ago. . Water at the base of the pump: 1. could be from a loose pump lid, dripping when the pump is off, 2. could be a leaking outlet pipe fitting, oozing from where water leaves the pump, and running down the sides of the volute, and dripping off the bottom, or 3. could be the shaft seal failing, behind the impeller. The pump shuts off because it trips the circuit breaker in the house. What are the amp and volt readings for the new cell? The pump has been running for 2 days. Loose wiring, or broken wires, or wires nearly touching each other, and arcing. BLUE-ESSENCE-20 20K GAL SALT CHLORINATION SYSTEM (HAY-45-0020) Product # : HAY-45-0020 Mfg : HAYWARD POOL PRODUCTS INC Mfg # : BLUE-ESSENCE-20 (FLORIDA ONLY) Department : FEEDERS | CHLORINATORS | SANTIZERS Product Line : Salt Generators UOM ( Default ) : EA Obsolete : This product is not obsolete. The board wasnt showing anything. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
1. What do I need to do to fix this? Put everything back in place, turned pool on. You dont need a seal plate kit you can just use the shaft seal SPX1600Z2. Could that be the voltage then or is there another possibility? Step 3: Double check the wires on the flow switch for damage. What do I need to replace the seal plate, the diffuser, the pump housing? Could the filter be plumbed backwards possibly? A pump that simply wont start is a frustrating problem. If thats not the problem, try soaking the fingers again, with a stronger solution, and/or leaving them soaking longer. I have a Hayward pump for my above ground pool, it is two years old. If I wait for a few minutes after that, the pump starts up again at full speed. Hi there, I have a 2-speed (hi and low) Hayward pump. My Hayward mother is a 1.5 hp. Give the cell an acid soak and it should clear the blockage. Hi Anmarie, Could be the wrong type of sand, but not likely if the bag said Pool Filter Sand on the label. Ours is doing the same thing. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Hi Kathy, the clicking could be the start switch in the rear of the motor, not fully disengaging. Hi Shannon, right now it is a defective capacitor, not sure about the rest of the motor, but is probably OK. If this is an ABG pool, check the skimmer hose and adapter fittings. If the capacitor doesnt fix it, you may need a new motor, or pump, barring other issues that can be seen readily. I assumed electrical issue but when I checked the voltage at the back of the motor and it was good I am at a loss. Hi Curt, not especially uncommon, small stress cracks on the outlet port of the pump, about 1/4 long? If they are within range, replace drive. Took it to pool mart and they cleaned it out and said everything was fine inside it. I put new sand it its still dumping could it have been sand still in the line what you think or is there anything else that could cause this I put 200 lbs of sand in which is the correct amount . For Drive Error Pump is Stalled error message, the first thing to check (as you did already) is that the motor shaft spins freely, and the impeller is not clogged. The trick is the little plug on the electrical panel MUST be moved to either 230 (up one) or to 115 (down). I just purchased a new pump and installed it but once all the hoses are connected even with the pump off the pump is leaking from the strainer housing. I will try that tonight. My pump seems to be working fine but Im having an issue with the flow pulsating out of the filter. I have a blue essense 20,000 salt system and can find very little online. Using a circuit tester, I determined that the timer and the inline switch has power. What happens if too much air gets in before the high speed kicks in? You can remove the pump basket and reach back with your fingers to see if any debris can be felt in the eye of the impeller (pump Off, of course, lol). If still nothing, look for damage in the rear of the motor, something burned, melted, loose, or pinched or cut wires. heres the motor: https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft and the seal: https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2. It happens every time. Then, I tried plugged the pump into another power outlet and it still does not work. it will not pull up off the pump basket. If your cell looks like 4B, follow the instructions below for cleaning your cell. Hi David, an air leak will always come from a point BEFORE the impeller. The air may be there on high speed too, its just not noticeable. 6. Please contact me at mbrad39972@hotmail.com. Thanks! If your pump plugs-in to an outlet, it could also be a bad outlet, or bad wire or connection from breaker to outlet. Fixing this issue can be tricky, so we suggest you get the help of a certified professional. Be sure that bare wires are not touching other bare wires or terminals, or other metals. If no power at motor, check connections for tightness, inspect wire and conduit for damage. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. Im having a problem with my super pump. Has been running great. I completely back washed and clean the system two times making sure the filter was put together properly and there were no holes in either the manifold or the filter grids. What could it be. The selector plug MUST be moved or the breaker will trip every time you try to start it up. Are I on the right track? I replaced the entire pump motor and the same thing happened. Hi Liane, a click coming from a control panel, could be a relay, clicking to send the signal to start the pump, but the signal is lost along the way. Hi, might have been a small clog in the pipe. Or you can try a filter cleaner first, to remove oils and scale that may be clogging the filter. Flip the switch opposite, and you should be all set. The symptoms you describe could be shorted windings, or it could also be just a bad capacitor, or it could be a motor that is locked up, from small amounts of rust inside which is often the case for motors that have sat all winter long. Inspect for any damage to wires or wire casing. Read up on it and seems it happens a lot and the motor drive needs to be replaced. The other rectifier is rated as 18-33 VDC. If the blower prover switch opens unexpectedly during operation the control will shut down and attempt to re-light. Theres a few ideas to check, good luck! If needed, you could replace just the motor, and the shaft seal, and save a few hundred bucks. This is a brand new pump out of the box that was installed and the inlet is drawing water in and filling basket and the outlet is discharging water but it just trips the breaker everytime. Push the diagnostic button until T-XX appears on the display. dr myers ultrasound. Lubricating the lid o-ring regularly will help improve the seal. One of them was arguably the best-constructed route from London [Marylebone] to Manchester. Suggestions ? Quite a criticism for something costing 33bn-plus. When the pump comes on a massive amount of bubbles comes out of the return line in the bottom of the pool. Davy, hayward blue essence troubleshooting It was wired for 230 but only had 115 going into it (we realized this after we had a pool guy come and see it) for a long time. I inspected the impeller and it looks fine except where the threads are there are tiny hairline fractions. 2. i put the hose down the skimmer outlet back to the pool to fill the pipes, still nothing. So it seems its changing speeds from slow to normal or is shutting off and immediately turning back on. Could be too much or too little sand, the filter should be about 2/3 full of sand. After I moved in a year ago. So My pool pump is two speed and I have it set to run for 3 hours in low speed and 5 in high. Air can also enter the system from low water level or a stuck skimmer weir, bringing air in from the skimmer, or from loose and leaky suction side (skimmer/main drain) valves. If you dont have a control system, and just a breaker box subpanel and maybe a time clock, the click could be coming from a switch inside the motor, which could be loose wires, low power, bad capacitor, loose switch, or something jamming up the motor shaft or internal fan. I have a new pump and brand new grid inside my filter i have no leaks after about 10 minutes my jets stop i back wash filter and it works for about 10 min again i am stumped. When it starts up it occassionally will blow the breaker. Hi Tony, there could be a short in the motor, or loose wires connecting to the capacitor, or if the capacitor you are replacing with is not the correct capacitor, or if the centrifugal or stationary switches are not releasing the capacitor, due to loose or misaligned switches, or loose wires, or wires shorting out by touching other wires or the motor casing, or crimped wires give a good look around the back of the motor, and try another capacitor, maybe call Hayward and ask for the correct capacitor MFD number for your horsepower of Northstar. JavaScript is disabled. Mt Tercer nivel ( dos elevadores ) 3 recamaras, Depto: 4 recamaras Salita de visitas Salita de TV 2, Diseado por travel organiser personalised. I was just wondering if you thought that could be the issue unless it could be something else. What are some items I should check assy A for on the bench so I can possibly repair it? How to Reset Inspect Cell Light - Hayward POOLSIDE Blog Is this normal operation or should I look into replacing the strainer cover o ring? We opened the pool a few weeks back with no pump motor problems. Almost like it was revving. I backwash and rinse and start again but it does the same thing. Any tips on getting the cover off to get to the capacitor (after removing the two screws)? New Assy is $500. It worked fine for the first 2-3 years and then every time it needs to restart, it trips the breaker. Press and hold the diagnostic button for 3 to 5 seconds. Missing air bleeder sock or strainer cap The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing Following this procedure will identify News Reporter Reveals On Live TV That Shes Been Secretly Recording We would like to show you a description here but the site wont allow us. We are a registered 501(c)3 non-profit that is funded by user donations. If thats not the issue, is the pump sized correctly for the filter, and not under/over sized? Old broken wires inside of the conduit could be the problem. Heres a link to the Hayward Heater Owners Manual, which may be helpful. stranger things backpack hot topic. Ryan, is the breaker a 15-amp? I have a Hayward power-flow matrix pump with hayward preflex extended cycle D.E. and loosing its prime . Hi We just bought a new Hayward Powerflo Matrix pump and filter. Within the underground world of Japan, and the world at large, a certain man is known as the Evil Emperor. Try to spin the impeller by hand, to be sure that the motor shaft spins freely and is not bound-up. I have a t-15 cell. If the capacitor is bulged or cracked, or looks like it is burned or charred, you can assume that it is D.O.A. Third possibility is the pipe size is too small, and your 90 gpm pump may be starved for water. There must be a leak. Hi Mike, it could be the start capacitor going, or it could be that one of the bearings is not quite perfectly flat, and if the shaft stops rotating at the right spot, it has trouble making the shaft turn, until bumped. I was only able to read and yes feel voltage in the pool when the main pump was running only. Nothin seems to be leaking anywhere. This is a black cylinder located in the back of the motor, at 9 oclock, which acts as a battery to give the motor extra juice to start. Flush out the housing to clear debris, then refill with water. Not sure what would cause that?!? Any insight would be helpful. The motor has all of the same specifications of the Hayward motor that is being replaced, what could possibly cause the motor not ot work? If all good, check the capacitor, at 9 oclock, looking for bulging or cracking or burned marks. Hi Carlos, Im not familiar with working on those timers, a built-in to the back cover for Power-Flo pumps. Don't stress! Hi Pat, yes they should be plug and play, was the cord attached already, or did you install? When I go to backwash the filter pump shuts down. I have a Haywood swim pro voyager and it is making a loud vibration noise.